Gazelle Cross Validator Documentation - Validator

General informations

Name
[ITI-38] XCA Query
AffinityDomain
eHDSI
Version
2025-09-08
OID
1.3.6.1.4.1.12559.11.30.1.2
Status
Available
Last modification by
cd2cc899-c02a-49ec-80e9-455547b2a467
Last modification on
9/9/25 10:38:44 AM (CEST GMT+0200)
Summary
Cross-verification of the messages that are part of the [ITI-38] XCA Query transaction (XCA messages, HCP Identity assertion, and audit messages) in the context of MyHeath@EU.

Inputs

The table below shows the documents/messages used by this validator

Kind
Keyword
Description
Message Type
Cardinality
Actions
XMLiti38_audit_ncpAAudit message issued by NCP A for ITI-38 transactionREQUEST1..1
XMLiti38_audit_ncpBAudit message issued by NCP-B for ITI-38 transactionREQUEST1..1
XMLiti38_requestOrderService:list requestREQUEST1..1
XMLiti38_responseOrderService list responseRESPONSE1..1

Configuration

Assertion Manager URL
https://gazelle.ehdsi.eu/AssertionManagerGui
Custom SVS Repository
https://gazelle.ehdsi.eu
Declared namespaces
  • xmlns:query = urn:oasis:names:tc:ebxml-regrep:xsd:query:3.0
  • xmlns:rim = urn:oasis:names:tc:ebxml-regrep:xsd:rim:3.0
DICOM to XML library
not applicable

Rules

Keyword
Status
Version
Severity
Description
assertions
Last modified on
Actions
iti38-documentUniqueId-audit-ncpAACTIVE0.1WARNINGThe country A should record, in the audit message, the documentUniqueId of all the entries returned to country B as part of the order service list response.09/9/25 10:38:44 AM (CEST GMT+0200)
iti38-documentUniqueId-audit-ncpBACTIVE0.1WARNINGThe NCP-B should record, in the audit message, the documentUniqueId of all the entries returned by country A as part of the order service list response.09/9/25 10:38:44 AM (CEST GMT+0200)
iti38-patientId-audit-ncpAACTIVE0.1WARNINGThe requested patient ID should be found in the audit message (ParticipantObjectIdentification) issued by NCP A.09/9/25 10:38:44 AM (CEST GMT+0200)
iti38-patientId-audit-ncpBACTIVE0.1WARNINGThe requested patient ID should be found in the audit message (ParticipantObjectIdentification) issued by NCP B.09/9/25 10:38:44 AM (CEST GMT+0200)
iti38-patientId-responseACTIVE0.1ERRORAll the documents returned by the country A shall be related to the requested patient ID.09/9/25 10:38:44 AM (CEST GMT+0200)

Covered assertions